Slit-Die Rheology (1 Temperature, 1 Die)


Test ID

R-035

Description

A capillary rheometer is used where the capillary die apparatus is replaced with a slit-die configuration. Slit die rheology measures true viscosity v. shear rate. The experiment is free from errors due to entrance and exit losses but is time-consuming to perform. The pressure is recorded at two positions within the die, one near the inlet and one near the outlet. 

Options

By positioning additional pressure transducers at other locations within the die, it is also possible to check if the pressure drop of the melt inside the flow channel is linear or not. Measurements can also be made using dies of different thickness.

Standards

  • ASTM D3835

Data

Shear Viscosity v. Shear Rate. This data appears in Matereality as Capillary Viscosity.

Replicates

Number of times this test is repeated: 1

Samples

1 kg of pellets [details]

Application

The data reported are useful in characterizing long glass fiber materials.

livechat button