Fiber Reinforced Thermoplastic for Simulation (Validation Package)


Test ID

Q-401

Description

Tensile tests are performed at strain rates of 0.001, 0.1 and 100 /s and three orientations taken only 50 mm from the gate of the plaque. All machining and molding is performed as described in Q-400.

Included Tests

3x M-235 Very High Speed Tensile Stress-Strain
6x M-204 Tensile Stress-Strain, Strength, and Modulus
1x SP-105 Specimen Machining Services

Options

Non-ambinet temperature testing is available for additional cost.

Samples

: 60 plaques

[details]

Application

This set of tests provide the required results needed to perform a validation of the fiber orientation material model described in Q-400. For strain measurements place a virtual extensometer at the standard 10 mm length and report strain from this extensometer; in addition place a second extensometer at the end of the radius section of the tensile bar (30 mm) to report displacement between these points.