Tensile Fatigue S-N Curve of Metals (up to 60 Hz)M-508M

Description

Tensile fatigue tests are performed per ASTM E466 at various stress levels to produce a cyclic stress versus cycles to failure curve (S-N curve). Each stress levels is repeated 3 times to account for variability. The default parameters for this test are 30 Hz, R=0.1 with expected failures from 1000 to 10 million cycles at 23°C. Prices vary by the parameters so please call if your parameters differ from these.

Options

This test can be performed as low as -55°C or as high as 1200°C. Frequencies, number of cycles, and stress ratio can be varied.

Standards

  • ASTM E466

Data

Cycles to Failure, S-N Curves. This data appears in Matereality as Tensile Fatigue.

Replicates

Number of times this test is repeated: 3

Samples

1 contact us

Application

An S-N curve is used to predict a materials fatigue life when subjected to repeated loading at various stresses. This property is critical for any application in which there is vibration or repeated motion under load.

Add to Cart
livechat button