GM CAE filled testing (tension up to 1000/s, shear flex, impact) 2 reps DIC per strain rate


Test ID

Q-505

Description

This Testpak includes testing to satisfy GM CAE testing requirements for filled materials. It covers 6 strain rates; 0.001-1000/s excluding 0.1/s. 2 reps of DIC per strain rate up to 100/s is performed. Testing is performed in three orientations, 0°, 45°, and 90°. Another tensile test using a full sized tensile bar is also performed. Shear tests in three orientations (0°, 45°, and 90°) are performed along with a density test. Flexural tests at 2 speeds and two orientations (0° and 90°) are performed. An impact test is also performed at 4.4 m/s and 2.2 m/s.

Included Tests

1x D-010 Solid Density
1x M-206 Tensile Stress-Strain, Strength, Modulus and Poisson's Ratio
9x M-204 Tensile Stress-Strain, Strength, and Modulus
15x M-204V 2D Tensile Stress-Strain, Strength, and Modulus using 2D DIC
6x M-232 High Speed Tensile Stress-Strain
3x M-235 Very High Speed Tensile Stress-Strain
3x M-219 Shear Stress-Strain
2x M-221 3 Point Flexural Stress-Strain, Strength and Modulus
2x M-230 High Speed 3 Point Flexural Stress-Strain
2x M-410 Dynatup Instrumented Impact
1x P-210 Test Specimen Photo Documentation
1x SP-105 Specimen Machining Services

Options

This TestPak may be ordered at elevated or cryogenic temperatures. If ISO 1110 conditioning is needed for your material, please add a P-111 test to your order.

Samples

: 275 plaques (4 x 12in)

[details]

Application

To Satisfy GM CAE specifications

livechat button